Process Instrumentation - Sales / Installation / Calibration

Process Instrumentation - Sales / Installation / Calibration

Calibration & Service

Calibration & Service

Pressure

Pressure

Gas Detection

Gas Detection

Sales, System Design, Installation & Calibration
a division of Aegis Safety Pty Ltd

Sales, System Design, Installation & Calibration

Techinspect is an instrumentation, gas detection, and electrical contracting company, with its head office located in Brisbane. Founded in 2004, Techinspect is a division of Aegis Safety Pty Ltd (a wholly Australian owned and run business) with a highly skilled workforce trained to provide quality service and products. Our operations cover everything from sales, system design and service to maintenance and installation. We are able to offer calibration services in our workshop located in Geebung or at your site by our on the road service team.

Download Company Profile
Additel, Honeywell Analytics, Intech Instruments, Sentech Corporattion
Our Suppliers include:

Additel, Honeywell Analytics, Intech Instruments, Sentech Corporattion

Additel - Pressure Gauges, Automated & Digital Pressure Calibrators, Process Calibrators / Honeywell - Portable & Fixed Gas Detection / Intech - Transmitters, Data Loggers, PLC multiplexers, Process Indicators, Microscan, SCADA & Recorders / Rhomberg - Pressure Gauges / Sentech - Refrigeration Monitors,

Gas Detection, Process Control, Pressure Gauges, Temperature Monitoring
Our Range of Products include:

Gas Detection, Process Control, Pressure Gauges, Temperature Monitoring

Automated & Digital Pressure Calibrators, Process & Loop Calibrators, Car Park Monitoring Systems from AmpControl & Honeywell Analytics, Sentech Refrigerant Leak Monitors, Rhomberg Pressure Gauges, Instrumentation - Temperature Monitoring Systems, PLC programming, SCADA, Data Loggers, Weather Stations and many more...

Calibration, System Design, Installation, Fault Finding
Our Services include:

Calibration, System Design, Installation, Fault Finding

With a dedicated temperature and pressure testing lab, Techinspect has all your calibration requirements covered. As well as calibrating portable equipment including portable gas detectors, pressure gauges, instrumentation at our workshop we provide on-site solutions for permanently installed systems including [but not limited to] car park gas detection, refrigerant leak monitors and temperature monitoring.

Contact Us for Pricing

GP-MC - Multi Purpose Data Logger

GP-MC - Multi Purpose Data Logger

 gp mc  

Product Specifications
Ordering Information
External Power Input
Logging Thermocouple inputs with the GP-MC

The GP-MC is a high resolution (12 bit) multi purpose data logger with eight analogue and two digital pulse inputs. It also provides a Start on Trigger input and two alarm outputs. The GP-MC can be supplied in an optional IP66 Weatherproof enclosure if required. It can be configured to accept input from a wide variety of sources including:

  • 4~20mA Probes
  • Voltage (DC)
  • Current (DC)
  • Temperature Probes
  • Pressure Probes
  • Flow Sensors
  • Frequency
  • Switches
  • Thermocouple
  • Potentiometers
  • Light Sensors
  • Leaf Wetness Sensor
  • Soil Water Tension Probes
  • Wind Speed Probes
  • Wind Direction Sensors
  • Tipping Bucket Rain Gauges
  • Solar Radiation Sensors

The GP-MC also has an internal temperature sensor for convenient logging of ambient temperature if desired.

One to Five year battery life depending on usage as below, user replaceable. Data is retained in the event of battery failure. Battery Status Monitor in Omni7 / OmniLog Software.

  • Warning: When using the Average, Maximum or Minimum reading(s), the logger reads the attached sensor(s) every second. This will reduce battery life.
  • Using the logger in temperatures below -5°C (23°F) will reduce battery life.

Download cable for GP-MC = DLC5USB [USB] or DLC5 [RS232] (Standard 2m DB9 Male/Female RS232 Serial Cable)


Order code:

Description:

GP-MC Multi Purpose data logger
Seahorse Optional IP66 Weather Proof Enclosure for GP-MC outdoor use
   

Standard Probe Sets; Other types available - Contact Intech Instruments:

mA-MC-PS One 4~20mA or 0~20mA input
##VD-MC-PS One Voltage input - available ranges are: 5VD-MC-PS = 0~5Vdc, 
10VD-MC-PS = 0~10Vdc, 24VD-MC-PS = 0~24Vdc, 32VD-MC-PS = 0~32Vdc. Or any voltage between 0 and 32Vdc.
Note: The maximum voltage input via probe set for the GP-MC is 32Vdc - for voltages above 32Vdc an intermediary transmitter like 
the PI-D must be used.
Pt1000-MC-PS Pt1000 Temperature Probe, range -50~130ºC
Note: GP-MC maximum Pt1000 temperature range is -100 ~ 400ºC
P###-MC-PS Pressure Probe - available ranges are: P100-MC-PS = -15~100psi, 
P300-MC-PS = -15~300psi, P500-MC-PS = -15~500psi
Flow-MC-PS Coil or open collector
ACM-MC-PS Flow metering off the pump run contact

Download options:


SWDL-DLC5USB
SWDL-DLC5
Omni7 / OmniLog Software (used with all TruTrack data loggers):
Omni7 / OmniLog Installation CD and USB download cable Kit
Omni7 / OmniLog Installation CD and RS232 download cable Kit
DLC5USB
DLC5
Spare download cable:
GP-MC USB download cable
GP-MC RS232 download cable (Standard 2m DB9 Male/Female RS232 Serial Cable)

 

Note: GP-MC inputs are individually configurable using Omni7 / OmniLog. Each input requires conditioning using a 'Probe Set' - see example picture below:

GP-MC Inputs

 

 

The GP-MC has an internal battery which powers the logger and probes. However, it can also be powered by an external 5V to 15V dc Plug Pack or Battery.
The main reasons for using the External power input are:

  • When large current draw from probes would flatten the Internal battery; and
  • At very low temperature (< 10ºC) where the Internal battery voltage can drop.
  • External power can also be used to run the logger while the internal battery is changed.

The Internal battery runs the logger if External power fails. There is an External Power Status Monitor in Omni7 / OmniLog software.

Please note that Intech Instruments' recommends the internal battery be left in place in case the external power supply fails. The internal battery will keep the logger going should this happen. More information below:

If the logger is run with no internal battery and the external supply fails the logger will turn off. When the external power supply is turned back on, the logger will reboot and will be in "Stopped" mode. The logger will need to be configured in "start on condition" mode and "loop" mode and the "Start Logger" button clicked to initialise the next recording cycle.
It is recommended that the internal battery is left in. No power is drawn from the internal battery when the external supply fails and the internal battery will keep the logger running during the down time. The logger will stay on standby and start on condition even if the external supply is still down.

 

A lot of people say thermocouple to mean temperature probes, where as if the temperature range they are measuring is between -50 and +200 degrees C, then Pt1000 is more accurate and cheaper to implement than thermocouple. The GP-MC accepts Pt1000 input (with the necessary resistors). Thermocouples are ideal for high temperature ranges.

The only way that the GP-MC can accept a thermocouple signal is via an intermediary transmitter like the XU Series with an output signal of 4~20mA.
mA-MC-PS input cables for each input from the XU Series transmitter(s) into the GP-MC are also required.


Manufacturer: Intech Instruments Ltd

From our General Manager

We have all your Pressure, Instrumentation and Gas Detection in the one place.

Craig Colhoun

Craig Colhoun

General Manager

Would you like to know how we can help you?

Request more Information